Used Oil is pre-heated in order to remove the moisture, light contaminants like glycol, solvent, lighter organics etc.
The incoming oil from the Raw Oil Storage Tanks is fed into the Dehydration Section after passing it through the final oil coming out of the Distillation column in order to maximize the heat recovery since heat recovery reduces the utility consumption. GOYUM Dehydration Column is specially designed in order to remove the light contaminants from the Used Lube Oil. The Heating arrangement is provided inside the column with steam inside the coils, with the optimum heat transfer area.
GOYUM Dehydration Column have the agitation system inside the column which ensures proper contact of oil with the heating surface and also avoid the cracking and fouling of the Used Lube Oil.
The Dehydrated Oil is then fed into the filters for removing the impurities inside the Used Lube Oil and then it is feed to the further process. The filters of the GOYUM are designed which are very easy to handle & operate with optimum filtration area.